STANDARD USER OPERATIONS FOR THE MACHINE
1. Turn the machine on with the ON/OFF switch. Heat up the pump with the condition program when machine has stood idle for
some time (instructions page 22).
2. Fill the vacuum bag with product. Select the correct format bag that easily ts around the product but is not too large for the
product. Ensure hygienic conditions during this operation. Packaging materials, product and hands must be clean and if
possible dry.
3. Lay the vacuum bag in the chamber or on the working plate. The open side must be laid over the
sealing bar or silicone holder. The bag may however not extrude from the chamber. If the product is
a lot lower than the height of the sealing bar or silicone holder then insertplates which are supplied
standard with the machine can be used. This makes the operation easier and reduces the cycle time.
4. The vacuum bag must be laid without folds over the sealing bar (Premier and Ultra)
5. For a gas ush system the opening of the vacuum bag must be pulled over the gas nozzles (see illustration).
6. Multiple vacuum bags can be placed over the sealing bar/silicone holder if the sealing bar/silicone holder is longer than the
vacuum bag. Vacuum bags may not however be laid on top of each other on the bar/holder. If there are multiple bars/holders
then all bars/holders can of course be used during the same cycle.
7. Use the [PROG] key to choose the desired program. See page 15 for instructions about programming.
8. Close the lid and the machine automatically runs through the full cycle of all activated functions. The lid opens automatically
when the last function “ventilation” has been completed.
9. If necessary the cycle can be partially or fully interrupted by pressing the [VACUUM STOP] key or the [STOP] key. The
[VACUUM STOP] key interrupts the active function (vacuum, gas ushing, sealing, or soft-air ventilation) and automatically
continues with the next function. The [STOP] key interrupts the entire cycle and goes immediately to the ventilation function.
10. After cycle completion, the packed product (or products) can be removed from the machine.
11. If the machine is equipped with a cut-off sealing system then the remaining ap on the vacuum bag can be torn off.
SAFETY and PRODUCT PROTECTION
The packing process can be partially or fully interrupted at all times:
Stop active function, press on [VACUUM STOP] key
Stop full machine cycle, press [STOP] key
OPTIMAL AND EFFICIENT PACKAGING RESULT
Use the correct size and good quality vacuum bags
Maximum 75% product lling in vacuum bag
Place vacuum bag fold free over sealing bar/silicone holder (use correct number in
insertplates in chamber)
Pull vacuum bag far enough over gas nozzles (for gas ush) so that no gas is lost and the
bag does not move during gas ushing
Page view 8