USER MANUAL PREMIER & ULTRA SERIES
The function values in a selected program number can be changed using either manual or automatic programming. For units,
range and limits of the function values refer to the previous chapter, MACHINE CONTROL PANEL.
10 programs can be selected and set, number 0 to 9. Note: program 0 cannot be programmed. The values in this program are
set for service and reference use.
MANUAL PROGRAMMING
Starting situation: machine is in normal operation mode and the lid is open.
A. Select the correct program with PROG 0-9 key for setting function values.
Program number is displayed on the small display.
B.
Press REPROG key to switch into program mode.
The program number now starts to blink on the small display.
C.
VACUUM
GASFLUSH
SEAL
SOFT-AIR
Select the required function for programming with the FUNCTION SELECT Key.
The indicator lights will turn on for the active functions when selected.
Remark on Seal function for option 1-2 cut-offseal
At option 1-2 cut-offseal, the indicator SEAL lights up twice when selected
The rst time is for setting the seal time and the second time for setting the cutting time.
Remark on option Digital Sensor Control
At option sensor control, the indicator VACUUM lights up twice when selected.
The rst time for the vacuum function (vacuum percentage)
The second time for the vacuum plus function (time duration), see pages 11,13
D.
VAC
STOP
STOP
Digital Time Control
Set the amount of time required for the selected function by using the + and – keys.
Digital Sensor Control
Set the percentage of vacuum required or the amount of time required for the selected
function by using the + and – keys.
Remarks
Set values are displayed on the large display. The functions vacuum plus (sensor control),
gas ush and soft air can be turned off in the programme if required. For turning off a
function press the – key until OFF appears on the large display.
E. Repeat steps C and D for setting other function values.
F.
Press the REPROG key after setting all relevant functions to store the changes in the
program. The control then automatically switches back to operation mode and the machine
is ready for use. The newly set values are now the new default values
PROGRAMMING