CONTROL PANEL LAYOUT CONT.
9. - / STOP Key
Function during cycle Terminates the program cycle completely. The cycle immediately switches to the ventilation
function.
Function in program mode` Lower the value of the selected function within the program selected in the program mode.
10. Vacuum meter
Displays the pressure in the vacuum chamber. See the following table for the relationship between the vacuum meter
and the percentage vacuum.
Position vacuum meter Vacuum percentage
00
0.2 20
0.3 30
0.4 40
0.5 50
0.6 60
0.7 70
0.8 80
0.9 90
- 1.0 99+
11. ON/OFF Switch
The ON/OFF switch is used to turn the machine on and off before and after operation. The switch turns on all units in the
machine. Caution, the switch does not completely remove all power from the machine.
OPERATION MODE
When the machine is turned on, the machine switches to operation mode after displaying the two codes (see page 4).
The operation mode is the standard setting of the control panel for packaging products. Set values cannot be modi ed in
operation mode.
With the PROG key and function selection keys the set values within the various programs can be viewed. If the
machine is ready to package a product (the product is already in the chamber), then all that needs to be done is to
choose the program (PROG key) and close the lid. The program cycle starts automatically running through the set
functions in the program.
Description of the program cycle for digital time control
1. Select the program number with the PROG key and the small display.
If the selected programme is programmed with the active gas ush function then a dot appears in the lower right hand corner
of the small display.
2. Close the lid.
3. Vacuum function The machine starts to vacuum the chamber.
The light in front of [VACUUM] goes on.
Large Display: decrementing time per second starting at the time set (max. 99 sec.).
Vacuum meter starts increasing to the left.
4. Gas ush function Once the vacuum function has completed then the gas ush function starts to ush gas into
(if installed) the vacuum chamber.
The light in front of [GAS] goes on.
Large Display: decrementing time per second starting at the time set (max. 99 sec.).
Vacuum meter starts decreasing to the right.